BRHR high efficiency residential HRUs

BRHR high efficiency residential HRUs


BRHR Series residential heat recovery devices offers 90% temperature efficiency and airflow rates of up to 500m3/h along with vertical, horizontal or ceiling mounting model options depending on your needs.

Our devices are designed to be plug-and-play, and equipped with advanced automatic control options, standard G4 filters, by-pass damper for free cooling, along with temperature and humidity sensors.

General Information

High efficiency heat exchange system with EC Fans

High efficiency hexagonal counter flow plastic plate heat exchangers offer up to 90% thermal efficiency. Our fans are self-motorized with energy saving EC motors and operate quietly. The metal casing is double walled, with 25mm insulation material in-between to ensure both high thermal performance and low noise levels.

Free-Cooling

On seasonal transitions (spring and autumn) when indoor and outdoor temperature differences are not significant, BSK Heat Recovery Units automatically switch to Free Cooling mode by opening the built-in bypass vent. The air will pass through this canal without going through the heat exchanger, so you can cool your house directly.

Humidity Control

Built-in humidity sensor can automatically set your BSK Heat Recovery Unit to Boost mode when a set level of humidity is reached in your house to quickly dissipate the moisture to prevent it building up. 

Defrost mode

We suggest that you equip a pre-heater for uses below 0 C to avoid freezing inside the unit, however to prevent this from happening when there is no heater attached, our devices automatically enter defrost mode when temperature requirements are not met. Defrost mode adjusts intake and exhaust air rates to prevent icing and keep the device temperature at a safe level. We strongly advise you to use a pre-heater for climate conditions below -10 C.

ModBus Compatible

Our units use ModBus protocol to connect and communicate with your building management system and report malfunctions or periodic maintenances. You can monitor and control your device through a computer or a central system.

Technical Specifications
Product Model BRHR 150 Slim BRHR 100 BRHR 150 BRHR 180 BRHR 220 BRHR 325
SEC Class A+
*SEC (Average) (kWh/(m².a)) -42.12 -42.82 -43.21 -43.52 -41.59 -42.22
SEC (Cold) (kWh/(m².a)) -80.8 -81.9 -82.66 -83.11 -79.49 -80.57
SEC (Warm) (kWh/(m².a)) -17.34 -17.81 -17.99 -18.21 -17.26 -17.62
Product Type Bidirectional Residential HRU
Drive Type Variable Speed Drive
Type of HRS Recuperative
Thermal efficiency of HRS 87% 90% 90% 90% 85% 85%
Max. Flow Rate (@100Pa) (m³/h) 160 170 185 185 485 495
Max. Electrical Power 60W 170W
Sound Power Level (Lwa) 37 dB(A)
Reference flow rate (m³/s) 0.032 0.035 0.035 0.038 0.094 0.103
Reference external pressure 50Pa
*SPI (@ Ref. flow & pressure) (W/(m³/h)) 0.24 0.22 0.22 0.21 0.22 0.21
Control Type Local Demand Control
Control factor 0.65
Internal / External leakage rate < 2%
Casing leakage class L2
Visual filter warning Yes (See User Manual for details)
Assembly instructions www.bskhavalandirma.com.tr
*AEC (Average) (kWh/a) 1.85 1.73 1.73 1.67 1.73 1.67
*AHS (Average) (kWh) 46.07 46.48 46.86 47.02 45.25 45.72
AHS (Cold) (kWh) 90.12 90.92 91.68 91.99 88.51 89.45
AHS (Warm) (kWh) 20.83 21.02 21.19 21.26 20.46 20.68
* AEC: Annual Electricity Concumption, AHS: Annual Heat Savings, SEC: Specific Energy Consumption, SPI: Specific Power Input
This document is prepared in accordance with the Commission Delegated Regulation (EU) No 1254/2014
Control Panel Opitons

Digital Control Panel

    

6 programmable fan speed levels
3 different, programmable Boost mode
Free-cooling mode
Weekly program
Automatic humidity control
Automatic heater control
Defrost mode
ModBus connection protocol


Manuel Control Panel

    

Fan speed controller
Filter full LED indicator


Accessories

F7 Pollen Filter


Our standard G4 filters offers good protection against dust and common particles, however you may need additional protection from pollens and other smaller particles especially if residents are allergic. We suggest the F7 grade pollen filters for such individuals.

Pre-heater

For subzero outside conditions, you should equip an electrical pre-heater to prevent ice forming inside the unit. This electrical pre-heater can connect to your BSK Heat Recovery Unit’s fresh air intake vent.

Water heater


If your house is already heated by hot water, you can equip duct type water coils to the supply air vent to further heat the incoming air for a precise control of temperature. For buildings without the option for a water heater, we also offer electrical heaters.

Silencer


We designed BSK Heat Recovery Units to be as quiet as possible; however you may need to further reduce the noise levels in some situations. You can add the duct type silencer or the flexible silencer for those tight spaces, to the supply vent and enjoy the silence.

Drainage siphon


Condensation inside the BSK Heat Recovery Unit is kept at a minimum but varying humidity and temperature levels may increase the precipitation. With this apparatus you can connect your unit to your existing water system and get rid of the water droplets hassle free.

CO2 Sensor

CO2 sensor allows automatic control for ventilation rate in crowded venues or houses with fireplaces. When the CO2 levels rise, your BSK Heat Recovery Unit increases ventilation rate to supply you with the best air quality.